DMC-18x6 Command Reference
45
BP
FUNCTION: Burn Program
DESCRIPTION::
The BP command saves the application program in non-volatile EEPROM memory. This
command typically takes up to 10 seconds to execute and must not be interrupted. The
controller returns a : when the Burn is complete.
ARGUMENTS: None
USAGE: DEFAULTS:
While Moving
No
Default Value
---
In a Program
Yes
Not in a Program
Yes
Controller Usage
ALL CONTROLLERS
RELATED COMMANDS:
Burn Parameters
Burn Variable
Note: This command may cause the Galil software to issue the following warning "A time-out occurred
while waiting for a response from the controller". This warning is normal and is designed to warn the user
when the controller does not respond to a command within the timeout period. This occurs because this
command takes more time than the default timeout of 5 sec. The timeout can be changed in the Galil
software but this warning does not affect the operation of the controller or software.