Galil Motion Control optcom Page 55
Optima DMC-1xxx and DMC-18x2 Command Reference
BV
i
44
BV
FUNCTION: Burn Variables & Arrays
DESCRIPTION::
The BV command saves the controller variables and arrays in non-volatile EEPROM
memory. This command typically takes up to 2 seconds to execute and must not be
interrupted. The controller returns a : when the Burn is complete.
ARGUMENTS: None
USAGE: DEFAULTS:
While Moving
Yes
Default Value
---
In a Program
Yes
Not in a Program
Yes
Controller Usage
ALL CONTROLLERS
OPERAND USAGE:
_BV returns the number of controller axes.
RELATED COMMANDS:
"BP"
Burn Program
Note 1: This command will store the ECAM table values in non-volatile EEPROM memory.
Note 2: This command may cause the Galil software to issue the following warning "A time-out
occurred while waiting for a response from the controller". This warning is normal and is designed to
warn the user when the controller does not respond to a command within the timeout period. This
occurs because this command takes more time than the default timeout of 5 sec. The timeout can be
changed in the Galil software but this warning does not affect the operation of the controller or
software.