Galil Motion Control cadman Page 5
MOVING_MACRO OFF and MOVING_MACRO ON are used to turn the dispenser on
and off based on its location in the drawing. Figure 4 shows the use of the
MOVING_MACRO's.
An alternate method for controlling the flow of adhesive is shown in Figure 5. LINETYPE
macros are used to associate a linetype with a series of DMC commands. In this example, a
solid line becomes associated with the SB1 command while a dashed line becomes associated
with the CB1 command.
Figure 3:
Placement of FIRST, LAST, SCALE and basic macros
Figure 4:
Final CAD drawing with dispenser control