Galil Motion Control note 1412 Page 6
ICM-1900
0
1
3
2
7
6
4
5
J5
J1
DMC-17x8
J6
J8
IOM-1964-80
ICM-1900
Provides Access to Signals for
Axes A-D via Screw Terminals
CABLE-100-1M (1 METER)
OR
CABLE-100-4M (4 METER)
IOM-1964-80
Provides Opto-Isolation and
Interconnection for Extended I/O
CB-50-80-1748
Adapts 2 50 Pin Ribbon Cables
for CABLE-80
(Ribbon Cables Included)
CABLE-26-25
Provides Connection for Auxiliary
Encoder Signals
26 Pin IDC to 25 Pin D-Type
Note: This cable is only required if
the Auxiliary Encoder Inputs will be
used.
DMC-17x8
1-4 Axes ISA
Bus Controller
with 64
Additional I/O
CABLE-80-1M (1 METER)
OR
CABLE-80-4M (4 METER)
Figure 1. DMC-17x8 Controller with recommended cables for system connection.
Note 1: The ICM-1900 interconnect module is recommended. For other methods of
interconnection, such as using the ICM-2900, please contact Galil.
Note 2: The IOM-1964-80 opto-isolation unit is recommended for the DMC-17x8. This
unit provides opto-isolation for the 64 extended I/O signals on the controller. The
extended I/O cables can be directly connected to Grayhill (Model 70GRCM32-HL) and
OPTO-22 (model G4PB24) opto-isolation modules. Please contact Galil for further
information.