DMC-1718 to DMC-1748:
NAME
TYPE
PURPOSE
CABLE-100-1M
OR
CABLE-100-4M
(1 Cable Required)
1 Meter, 100 Pin High
Density Cable
4 Meter, 100 Pin High
Density Cable
Connects the DMC-1700 to an ICM-
1900 and provides all connections for
Axes A-D except auxiliary encoder
inputs.
CB-50-80-1748
(1 Required)
2 x 50 pin Ribbon Cables
with the CB-50-80 Adapter
Board, 1 Meter Length
Adapts 2 50 Pin Ribbon Cables for
CABLE-80
(Ribbon Cables Included)
Provides connection to IOM-1964 for
accessing extended I/O.
(Ribbon Cables Included).
CABLE-80-1M
OR
CABLE-80-4M
(1 Cable Required)
1 Meter, 80 Pin High
Density Cable
4 Meter, 80 Pin High
Density Cable
Connects the DMC-17x8 to an IOM-
1964-80 via the CB-50-80-1748
Note: This cable is only required if the
Extended I/O will be used.
CABLE-26-25
(1 Cable Required)
26 Pin IDC to 25 Pin D-
Type, 1 Meter Length
This cable connects the DMC-17x8 to
the ICM-1900 and provides connection
for Auxiliary Encoder Inputs for Axes
A-D
Note: This cable is only required if the
Auxiliary Encoder Inputs will be used.
ICM-1900
(1 Required)
Interconnect Module
Provides screw terminals for access to
all signals from the controller
IOM-1964-80
Opto-Isolation Module for
Extended I/O. Connects to
CABLE-80
Provides opto-isolation for extended
I/O and allows easy access via screw
terminals.
Note: This module is only required if
the Extended I/O will be used.