Sunpower USA SDR 232 XCX Page 3
MODEL NO.: SDR-2323CX~8CX REV.:0.3
UL/cUL/TUV STANDARD
RS010319
3/3 2001/10/05
3-4. SHORT CIRCUIT PROTECTION :
WHEN OUTPUT SHORT TO GROUND, THE POWER SUPPLY WILL SHUTDOWN.
AND AUTO RECOVERY WHEN SHORT CIRCUIT CONDITION HAS BEEN REMOVED .
3-5. POWER GOOD SIGNAL :
POWER ON WITHIN 100----500ms, high level ttl SIGNAL RELEASE.
3-6. PS-ON :
TTL SIGNAL, ACTIVE LOW FOR POWER SUPPLY TURN ON.
3-7. POWER FAIL ALARM :
IF ONE POWER MODULE FAIL OR TURN OFF, THE BUZZER WILL BEEP, AND TTL
SIGNAL WILL ON LOW.
3-8. FAN FAIL ALARM :
ONE POWER MODULE FAN FAIL OR SYSTEMS FAN FAIL , THE BUZZER WILL
BEEP AND TTL SIGNAL WILL ON LOW.
4. MECHANICAL DATA :
4-1. SDR-2323CX & SDR-2324CX DIMENSION : W 110 ××××D 220 ××××H 83.5 mm
4-2. SDR-2326CX DIMENSION : W 100 ××××D 250 ××××H 83.5 mm
4-3. SDR-2327CX & SDR-2328CX DIMENSION : W 228.6 ××××D 225 ××××H 42.6 mm
5.COOLING:
FORCED AIRFLOW COOLING WITH DC FAN IN EACH MODULE.
6. SAFETY :
THIS PRODUCT IS DESIGN TO COMPLY WITH THE FOLLOWING STANDARDS :
6-1. UL 60950 3rd EDITION (2000) STANDARD.
6-2. CSA C22.2 NO.60950 3rd EDITION (2000) STANDARD.
6-3. TUV EN 60950 3rd EDITION (2000) STANDARD.
6-4. IEC 60950 3rd EDITION (1999) STANDARD.
6-5. EMKO-TSE (74-SEC) 207/94 STANDARD.
7. EMS :
THIS PRODUCT IS DESIGN TO COMPLY WITH THE FOLLOWING STANDARDS :
7-1. EMI
(1) . FCC CFR 47 PART 15 SUBPART J , CLASS B LIMIT
(2) . EN 50081-1:1997 EMISSION STANDARD
EN 55022: 1997 CLASS B LIMIT
(3) . CNS 13438 CLASS B.
7-2. EMS
(1) . EN 50082-1 (1997) IMMUNITY STANDARD: