Sunpower USA RPM 280 X Page 2
MODEL NO.:
RPM-2801~2808S
REV.:0.2
UL/cUL/TUV STANDARD
RS010433
2/2
2001/11/01
1. AC INPUT :
1-1.VOLTAGE :
115V : 90V (MIN.) - - - 132V (MAX.)
230V : 180V (MIN.) - - - 264V (MAX.)
*AC INPUT 115V/230V AUTO RANGE OR MANUAL SELECTABLE.
RPM-2801,2803,2805,2807,2807S: AC INPUT VIA FRONT SIDE.
RPM-2802,2804,2806,2808,2808S: AC INPUT VIA REAR SIDE.
1-2. FREQUENCY :
47--------63Hz.
1-3. CURRENT :
(SINGLE MODULE)
10
A MAX. AT 115V AC INPUT, FULL LOAD CONDITION.
5
A MAX. AT 230V AC INPUT, FULL LOAD CONDITION.
1-4. INRUSH CURRENT:
(SINGLE MODULE)
40A
MAX. AT 115V AC INPUT, FULL LOAD CONDITION.
80A
MAX. AT 230V AC INPUT, FULL LOAD CONDITION.
* COLD START, AT 25AMBIENT.
1-5. LEAKAGE CURRENT:
2mA
MAX. AT 264V AC INPUT.
2. DC OUTPUT:
2-1. MODULE OUTPUT:
VOLTAGE
+5V +12V -12V
MIN. LOAD
2 A
0.5 A
0 A
MAX. LOAD
40 A
16 A
1 A
2-2. SYSTEM OUTPUT:
OUTPUT
V1 V2 V3 V4
VOLTAGE
+5V +12V -5V -12V
MIN. LOAD
2 A
0.5 A
0 A
0 A
**MAX. LOAD
40 A
20 A
*0.5 A
*1 A
***REGULATION
+5/-4%
±
±
±
±
5%
±
±
±
±
5%
±
±
±
±
5%
RIPPLE & NOISE (MAX.)
50mV 120mV 50mV 120mV
OVP
+5.8V~+7.0V ---
---
---
EFFICIENCY (TYP.)
65%
* -5V & -12V TOTAL OUTPUT MAXIMUM
12 WATTS
.
** TOTAL OUTPUT MAXIMUM
400 WATTS
.
*** THE OUTPUT voltage load regulation IS LESS THAN THE VALUES IN THE ABOVE
TABLE BY CHANGING EACH OUTPUT LOAD ±40% FROM 60% RATED OF LOAD, AND
KEEP
THE
OTHER OUTPUTS AT 60% OF RATED LOAD.