1. AC INPUT :
1-1.VOLTAGE :
90
V (MIN.) - - -
264
V (MAX.)
UNIVERSAL FULL RANGE.
RPM-2601P,2603P,2605P,2607P,2607SP: AC INPUT VIA FRONT SIDE.
RPM-2602P,2604P,2606P,2608P,2608SP: AC INPUT VIA REAR SIDE.
1-2. FREQUENCY :
47--------63Hz.
1-3. CURRENT :
(SINGLE MODULE)
5
A MAX. AT 100V AC INPUT, FULL LOAD CONDITION.
1-4. INRUSH CURRENT:
(SINGLE MODULE)
60A
MAX. AT 115V AC INPUT, FULL LOAD CONDITION.
100A
MAX. AT 230V AC INPUT, FULL LOAD CONDITION.
* COLD START, AT 25AMBIENT.
1-5. LEAKAGE CURRENT:
2mA
MAX. AT 264V AC INPUT.
1-6 POWER FACTOR CORRECTION CIRCUIT. MEET IEC 1000-3-2 CLASS D STANDARD.
(P.F. > 0.95)
2. DC OUTPUT:
2-1. MODULE OUTPUT:
VOLTAGE
+5V +12V -12V
MIN. LOAD
6 A
0.5 A
0 A
MAX. LOAD
30 A
15 A
1 A
2-2. SYSTEM OUTPUT:
OUTPUT
V1 V2 V3 V4
VOLTAGE
+5V +12V -5V -12V
MIN. LOAD
6 A
0.5 A
0 A
0 A
**MAX. LOAD
30 A
15 A
*0.5 A
*1 A
***REGULATION
+5/-4%
±
±
±
±
5%
±
±
±
±
5%
±
±
±
±
5%
RIPPLE & NOISE (MAX.)
50mV 120mV 50mV 120mV
OVP
+5.8V~+7.0V +13.8V~+17.5V
---
---
EFFICIENCY (TYP.)
65%
* -5V & -12V TOTAL OUTPUT MAXIMUM
12 WATTS
.
** TOTAL OUTPUT MAXIMUM
300 WATTS
.
*** THE OUTPUT voltage load regulation IS LESS THAN THE VALUES IN THE ABOVE
TABLE BY CHANGING EACH OUTPUT LOAD ±40% FROM 60% RATED OF LOAD, AND
KEEP
THE