Sunpower USA RAM 2667 8 Page 5
MODEL NO.:
RAM-2667~2668S
REV.:1.1
UL/cUL/TUV APPROVED
RS020338
5/6
2002/12/24
5.COOLING:
FORCED AIRFLOW COOLING WITH A
37 CFM
(MIN.) DC FAN IN EACH MODULE.
6. SAFETY :
THIS PRODUCT IS DESIGN TO COMPLY WITH THE FOLLOWING STANDARDS :
6-1. UL
1950 3rd
EDITION APPROVED. (E 129733)
6-2. CSA C22.2 NO.
950 3rd
EDITION
APPROVED BY UL.
6-3. TUV EN 60950: 1992
+A1+A2+A3+A4+A11
(1997)
APPROVED.
(R 3-02055423)
6-4. IEC 60950:1991+
A1+A2+A3+A4 (1996)
APPROVED.
6-5. EMKO-TSE (74-SEC) 207/94 APPROVED.
7. EMC :
THIS PRODUCT IS DESIGN TO COMPLY WITH THE FOLLOWING STANDARDS :
7-1. EMI
(1) . FCC CFR 47 PART 15 SUBPART J , CLASS B LIMIT
(2) . EN 50081-1:1997 EMISSION STANDARD
EN 55022: 1997
CLASS B LIMIT
(3) . CNS 13438 CLASS B.
7-2. EMS
(1) . EN 50082-1 (1997) IMMUNITY STANDARD:
EN 61000-4-2 : 1995 ELECTROSTATIC DISCHARGE STANDARD.
EN 61000-4-3 : 1996 RADIATED RF STANDARD.
EN 61000-4-4 : 1995 FAST TRANSIENT/BURST STANDARD.
EN 61000-4-5 : 1995 LIGHTNING SURGE STANDARD.
EN 61000-4-6 : 1996 CONDUCTED RF STANDARD.
EN 61000-4-8 : 1993 POWER FREQ. MAG. FILELD STANDARD.
EN 61000-4-11:1994 VOLTAGE DIP & INTERRUPT STANDARD.
8. PHYSICAL ENVIRONMENT (AMBIENT) :
8-1. TEMPERATURE RANGE :
OPERATING TEMPERATURE RANGE :
0 ~ 70
DERATING FACTOR
45 ~ 70
:
2.0
%
STORAGE
-10 TO +75
8-2. HUMIDITY :
OPERATION 20% TO 85% RH. (NON CONDENSING)
STORAGE AND SHIPPING 10% TO 95% RH. (NON CONDENSING)