ETA-USA zwb 60 3x w Page 2
ETA USA
16170 Vineyard Blvd. Suite 180, Morgan Hill, CA 95037
Visit us at: www.eta-usa.com
Phone: 1-800-ETA-POWER, (408) 778-2793 Fax: (408) 779-2753
email at: sales@eta-usa.com
Note: 1. Peak to Peak with 20MHz bandwidth with a tantalum 10uF in parallel with a 0.1 uF ceramic capacitor.
2. All output power load should not exceed 60W
3. Minimum load are required.
D
D
I
I
M
M
E
E
N
N
S
S
I
I
O
O
N
N
D
D
I
I
A
A
G
G
R
R
A
A
M
M
(
(
m
m
m
m
)
)
All the models
except
the ZWB60-33512X-W:
Environmental Specification
Operating Temperature
0 to +40
°C
Storage Temperature
-10 to +70
°C
MTBF demonstrated
>80'000 hours at full load and 25
°C ambient temperature
Environmental Agencies
Safety Standards
UL 60950 CSA 22.2-No.60950 TUV EN60950
EMI Standards
CE CISPR 22 Class B EN 55022 Class B
Protection
Over Voltage Protection
115-135% on +5V only
Over Load Protection
Over load protected @ 110% to 160%
Mechanical
Dimension [mm]:
L127×W76.5×H26mm (3"×5")