ETA USA
16170 Vineyard Blvd. Suite 180, Morgan Hill, CA 95037
Visit us at: www.eta-usa.com
Phone: 1-800-ETA-POWER, (408) 778-2793 Fax: (408) 779-2753
email at: sales@eta-usa.com
*1: Rated input voltage range for safety standard application is 100-240V AC 50/60Hz
*2: Input volt :100/200V AC, full load, Ta:25
*3: Input volt :100/200V AC, full load, Ta:25 , cold start Specification may differ
depending on temperature or power on again because of power thermistor.
*4: Over-load protection: constant current limit with automatic recovery.
*5: Output shutdown method. Output returns by power on again.
Environmental Specification
Operating Temperature
-10 to +70 °C
Operating Humidity
20~90%RH
Storage Temperature
-20 to +75 °C
Storage Humidity
10~95%RH (no dew condensation permitted)
Cooling Natural
Cooling
Dielectric Strength
Input-output 4000V AC for 1 min
Input-FG 2000V AC for 1 min
Withstand Voltage
Output-FG 500V AC 1min 1500V AC 1min
500V AC 1min
Insulation Resistance
Input-output 100M or more at 500V DC
Input-FG 100M or more at 500V DC
Output-FG 100M or more at 500V DC
Function
Over Current Protection *4
10.5A 5.25A 4.2A 2.62A
Over Voltage Protection *5
5.756.75V 13.816.2V 17.320.3V 27.632.4V
Remote Sensing
N/A
Remote On/Off control
N/A
Operational status indicator
None
Environmental Agencies
Safety Standard
Based on IEC60601 EN60601 UL60601 IEC60950
EMI
EMS
Based on FCC Class B CISPR11-Class B VCCI Class B
Harmonic correction
IEC61000-3-2 A-14
Structure & Others
Series Operation
Permitted
Parallel Operation
Not Permitted
Leakage Current
0.06mA/0.12mA
Vibration Resistance
510Hz:amplitude 10mm, 1055Hz:sweep 1min.
Acceleration:19.6m/s2 direction:X,Y,Z for 1 hour each
Shock Resistance
196 m/S
2
or less
Mechanical
Dimension [inch]
37x76.2x127 37×78.7×127
37×76.2×127
Weight [g](typical)
250g