ETA-USA Tel: 408-778-2793 Fax: 408-779-2753 e-mail: sales@eta-usa.com
6) ENVIRONMENT
6.1)MTBF(theoretical)
:
at 25°C ambient temp and nominal load, according to MIL-217F:100,000hrs above.
6.2)The adapter must be able to withstand the following environment:
·
Operating conditions:
§
Temperatures: 0°C to +70°C
Remark : Derate linearly from 100% load at 50
°
C to 50% load at 70
°
C
§
Relative humidity (without condensation): 10% to 95%
·
Storage conditions:
§
Temperatures: -40°C to +85°C
§
Relative humidity (without condensation): 5% to 95%
7) MECHANICAL CHARACTERISTICS:
·
Connections:
Input connector: IEC-320-C14 inlet
Output Connector assignment: Please see attachment Center "+"
·
Construction:
Desktop enclosure plastic case shown as attachment
.
·
Marking:
It will appear on an appropriate position, which will show model number, input/output
rating and other relevant description.
·
Weight:
400~550gs approximate
Parameter
Test Condition
Min. Typ. Max. Unit
Vps
Dielectric withstanding Voltage for primary to secondary
Primary to Secondary
5656
VDC
Vpg
Dielectric withstanding Voltage for primary to ground
Primary to Ground
2121
VDC
Ri
Isolation Resistance
Test voltage500VDC
50
M
CISPR EMI requirements for CISPR-11
Vin 220VAC
B
CLASS
FCC
EMI requirements for FCC Part-15
Vin 110VAC
B
CLASS