ETA-USA Tel: 408-778-2793 Fax: 408-779-2753 e-mail: sales@eta-usa.com
Specifications
OEQ**SC/WC2448
3WATTS/SINGLE/2 OUTPUT
Output Voltage [V]
+12
-12
+15
-15
Output Current [A]
Voltage Tolerance +/-[mV](maximum) *2
240
240
300
300
Ripple and Noise [mVp-p](maximum) *3
Regulation
a.Static Line Regulation [mV](maximum)
60
60
75
75
b.Dynamic Line Regulation +/-[mV](maximum) *4
480
480
600
600
c.Static Load Regulation +/-[mV](maximum) *5
1200
1200
1500
1500
+/-[mV](maximum) *6
480
480
600
600
+/-[mV](maximum) *7
60
60
75
75
d.Temperature Coefficient *8
e.Drift[mV](maximum) *9
75
75
90
90
480
480
600
600
g.Recovery Time *4,*10
Rise up time
Hold up time
Functions
Overcurrent Protection
>=110% of Rated Output Current [A]
0.143
0.143
0.111
0.111
Overvoltage Protection
Remote Sence
Trimming of output voltage[mV]
Input Fuse
Operating Temperature
(derating)
Operating Humidity
Storage Temperature
Storage Humidity
Withstanding Voltage
Isolation Resistance
Capacitance(input-output) [pF](typical)
Vibration
Shock
Cooling
Weight (typical)
open board type:7g
2200
5-10Hz:10mm double amplitude,10-55Hz:2G,20minutes' period for 60minutes each along X,Y,Z axes(non-operating)
,R
0G
Convection
-20 to +85
o
C
20 to 90%/RH(non-condensing)
Primary-Secondary AC500V for 1minute
Primary-Secondary 50M
(minimum) by DC500V insulation tester
Environmental
-20 to 71
o
C
3.5%/
o
C (50
o
C to 71
o
C) (out of warranty >= 71
o
C )
20-90%/RH(non-condensing)
Not available
Not available
Not available
Installed
Current Limiting with automatic recovery at discontinuous short circuit conditions
0.55
0.275
0.22
0.143
20mS(typical)
10ms(typical) at rated input/output
Not specified
200
480
600
960
0.03%/
o
C(maximum)
40
75
90
135
25
60
75
120
200
480
600
960
100
25
60
75
120
0.013-0.13
0.010-0.10
100
240
300
480
0.5
0.25
0.20
0.130
5
12
15
24
Model
OEQ05SC2448 OEQ12SC2448 OEQ15SC2448 OEQ24SC2448 OEQ22WC2448 OEQ23WC2448