               ETA USA      
              16170 Vineyard Blvd. Suite 180, Morgan Hill, CA 95037                                 
         Visit us at: www.eta-usa.com 
             Phone: 1-800-ETA-POWER, (408) 778-2793 Fax: (408) 779-2753  
      email at: sales@eta-usa.com 
Output 
 
Models 
Characteristics 
Unit 
ETD1.8SC300 
ETD2.5SCx 
ETD3.3SCx 
ETD05SCx 
ETD12S
Cx 
ETD15SCx 
ETD24SCx 
ETD48SCx 
Output Voltage 
Vdc 
1.8 2.5 3.3 5 
12 
15  24  48 
Output Current  
A 
25 25 25 20 
8.4 
6.7 4.2 2.0 
Voltage Adjust Range 
% 
±
10% of rated output voltage 
Ripple and Noise (max.)  *3 
mV 
150 
150  150 150 220  250 
340 
580 
Regulation
Regulation
Regulation
Regulation
 
a. Statistic Line Regulation (max.) 
mV
 
20 26 40 
100 
120 
120 120 
b. Statistic Load Regulation (mx.) 
mV
 
23 30 45 
110 
135 
135 135 
c. Temperature Coefficient *4 
%/
°
C 
0.75 1  1.5 
3.6 
4.5 7.5  15 
d. Drift *5 
mV
 
28 32 32 
75 
90 135 260 
mV
 
200 250 250 
600 
750 1200 1200 
Rise up time 
mS 
500mS(maximum) at 25C and rated input/output 
Hold up time 
mS 
Not specified 
Function/Protection 
Over current Protection (min.) 
105% of Rated Output Current [A] 
Current Limiting. Output shutdown when voltage drops to 50% of rated output voltage (60% at 
ETD1.8SC300) turn on 1minute after shot down to restart. 
Over voltage Protection 
115% of Rated Output voltage (min)  
Turn on 1minute after shutdown to restart 
Remote Sense *7 
Available 
Remote On/Off *8 
Available 
Environmental Specification
 
Operating Temperature 
-10 to +50
°
C 
Operating Humidity 
20-90%/RH (non-condensing) 
Storage Temperature 
-20 to +85
°
C 
Storage Humidity 
20 to 90%/RH  
Withstanding Voltage 
Primary-Secondary     AC 2'000V at 20mA for 1minute
(for 300vdc input: Primary-Secondary     AC 
3,000V  
                                                                                                        at 20mA for 1minute)
 
Primary-Frame Ground AC 2,000V at 20mA for 1minute 
Secondary-Frame Ground   AC 1,000V at 20mA for 1minute 
Isolation Resistance 
Primary-Secondary-Frame Ground   100M ohm (minimum) by DC500V insulation tester 
Vibration 
5-10Hz: 10mm double amplitude, 10-55Hz: 19.6m/s2, each along X, Y, Z axes (non-operating) 
Shock 196m/s2 
Cooling Convection 
Environmental Agencies
 
SAFETY 
UL 60950, EN60950, CE 
Mechanical Specification
 
Dimension [mm] 
65(W) x101 (D) x34 (H) mm (Not include output terminal)
 
Weight  (typical) 
200g 
*1 vary depending on input/output conditions 
*2 at rated input and rated output 
*3 measured by a bayonet probe at the end of a pair of 150cm long wires terminated with a 100uF electrolytic capacitor and a 0.1uF film  
     capacitor in parallel at a 0 to 100MHz bandwidth 
*4 within the operating temperature 
*5 for 7hour period after 1hour warm-up at 25C and rated input/output   
*6 when output current changed between 25% and 75% of rated output current rapidly at rated input 
*7 Line drop: Maximum 0.3V(Maximum 0.1V for ETD1.8SC300, 0.15V for ETD2.5SC300, 0.2V for ETD3.3SC300) 
*8 IC=maximum 10mA