FEATURES
MODEL SELECTION
SPECIFICATION
PARAMETER
Input Voltage
Transient Input Voltage
Operating Case Temperature
Storage Temperature (Ambient)
Wave Soldering temperature
MIN
-40
MAX
0 60
100
-40 100 °C
10
5
260
UNITS
Vdc
Vdc
°C
°C Applied for 10 seconds
CONDITIONS
Continuous
100 msec max.
ABSOLUTE MAXIMUM RATINGS:
Exceeding absolute maximum ratings may cause permanent damage and reduce reliability
EPBD-05SC36-A 20-65 5 10 50
Model Name
Vin
(Vdc)
Vout
(Vdc)
Io
(Amps)
Watts
1
DC-DC Converters
18~60Vdc Input
EP
BD
50 WATT
Size: 61.0mm x 58.4mm x 12.7mm
(2.40in. x 2.30in. x 0.50in.) (Typical)
Power Density Exceeding 18.11
W/in
3
Constant Switching Frequency of 350KHz
-40 to +100 degC Operation
Low Output Noise
Metal Baseplate
Very Wide Input Voltage Range : 18~60Vdc
Output Over Voltage Protection
Current Limit/Short Circuit Protection
Open frame construction
Logic ON/OFF
Safety Agency Compliant --TUV, UL, cUL
Terminal Strength
22 N Applied for 10 seconds
INPUT SPECIFICATIONS:
Test condition: -40
°C
<Tcase<100
°C; 18V<Vin<60V, Pout=50W, unless otherwise specified.
PARAMETER MIN TYP MAX UNITS CONDITIONS
Operation Input Voltage (V
in
)
18
60
Vdc
After start up
Maximum Input Current (I
in,max
)
5
A
V
in
=18
V
to 60
V
,any load
condition.
Input Reflected-Ripple Current ( Peak
to Peak)
100
mAp-p
0 to 20
MHz
, 12
uH
source
impedance, See
Figure 1
.
Input Transient
1
A
2
t
Start-up Input Voltage
19
20
Vdc
Shut-off Input Voltage
17
18
Vdc
Hysteresis
1.5
2
2.5
Vdc
EMC Conducted Margin
10
dB
ETS 300 386-1 Section
7.2.3, see