ETA-USA Tel: 408-778-2793 Fax: 408-779-2753 e-mail: sales@eta-usa.com
1) INPUT
Description
Min.
Nominal
Max.
Condition
Input Voltage
90VAC
115/230V
264VAC
Auto Range; 50/60Hz
Input Current(rms)
0.3A@264Vac 0.5A@90Vac
Line Frequency
47Hz
50/60Hz
63Hz
-
Efficiency
>70% 115VAC at full load (DC Conversion)
EMI: FCC Class B; CISRP22 Class B; EN 55022 Class B
2) OUTPUT
2.1) *Voltage Regulation
:
±
5%
*Hold up time:
10ms typical at full load @ 115VAC
DESCRIPTION
MODELNO.
NOMINAL
MAX. POWER
MIN. OUTPUT
MAX.OUTPUT
RIPPLY&
American type
European type
VOLTAGE
CURRENT
CURRENT
NOISE
+5V
0.5A
1A~2A
50 mV
WTM12-0512FWX-W WMM12-0512FWX-W
+12V
12W
0.1A
0.1A~0.8A
120 mV
NOTE: 1. Peak to Peak with 20MHz bandwidth and 10uF in parallel with a 0.1uF capacitor.
2.+5V and +12V combined load should not exceed 12W
3) PROTECTION:
·
OVER VOLTAGE PROTECTION(OVP)
·
AC RECYCLE SHORT CIRCUIT PROTECTION
·
OUTPUT SHORT CIRCUIT PROTECTION(<0.03 OHM)
·
AUTO RECOVERY
4) ENVIRONMENT
Operating
Temperature
0
°
C to 40
°
C
Storage Temperature
-10
°
C to +70
°
C
MTBF:
100'000 hours at full load and 25
°
C
ambient temperature.
5) SAFETY REQUIREMENTS
UL 1950
CSA 22.2-234
TUV EN60950
IEC 950
CE: EMC &LVD
GENERAL SPECIFICATION
This specification describes the
performance characteristics of a grounded,
single phase, 12 Watts, Dual Output
Switching Adapter.
12 WATT
DUAL OUTPUT SWITCHING ADAPTOR
WALLMOUNT
WTM12-FWX-W/WMM12-FWX-W SERIES