OVERLOAD PROTECTION
An over load protection will be effected when overloading reaches +160% MAX.
The power supply will not be automatically recovered after the overload being removed.
A manual power reset is necessary.
3.4)
VIBRATION:
10-55Hz amplitude (sweep 1 min.) less than 2G X, Y, Z 1 hour ea.
3.5)
SHOCK: <20G
4) ENVIRONMENT:
4.1)
Operating temperature:
Temperature
0 to 40 degree
Relative Humidity 20 to 90 percent, non-condensing
4.2)
SHIPPING AND STORAGE:
Temperature -25 to +85 degree centigrade
Relative Humidity 20 to 90 percent, non-condensing
5) SAFETY REQUIREMENTS(MEET)
The adapter must comply with UL/CSA/TUV/IEC950 standards.
5.1)
DIELECTRIC WITHSTAND
--- Primary to Secondary : 1500 VAC for 60 Sec.
--- Primary to Frame Ground : 1500 VAC for 60 Sec.
5.2)
INSULATION RESISTANCE
--- Primary to Secondary : 50 Meg. Ohms Min. 500 VDC
--- Primary to Frame Ground : 50 Meg. Ohms Min. 500 VDC.
6) ELECTROMAGNETIC COMPABILITY
Tests for conformance to this requirements will be performed with host system.
6.1)
FCC Requirements
The adapter shall comply with the FCC rules and regulations Part 15, Subpart J, "Class B" limits.
6.2)
CE Requirements
The adapter shall confirm to the "Class B" requirements of EN55022.
7) RELIABILITY
MTBF: 80000 hours min. at max. load for 25 degree centigrade ambient temperature.