ETA-USA Tel: 408-778-2793 Fax: 408-779-2753 e-mail: sales@eta-usa.com
Specifications
PFD21HWX
120WATTS(Peak 360W)/2 OUTPUTS
Input Voltage
Input Current
Input Range
Input Frequency
Input Frequency Range
Phase
Inrush Current *1
Efficiency [%] (typical)
Power Factor (typical)
Output Voltage [V]
Output Current [A]
Voltage Adjust Range
Ripple and Noise [mVp-p](maximum) *2
Regulation
a.Line Regulation [mV](maximum)
b.Load Regulation [mV](maximum)
c.Temperature Coefficient *3
d.Drift[mV](maximum) *4
e.dynamic load regulation [mV](typical) *5
f.Recovery Time *5
Rise up time
Hold up time
Overcurrent Protection
Overvoltage Protection
Remote Sense
Remote On/Off
Power Fail Detection
Parallel/series Operation
Operating Temperature
Operating Humidity
Storage Temperature
Storage Humidity
Isolation Resistance
Shock
Cooling
Leakage Current
Line Hamonic Distortion
Weight (typical)
MTBF [H]
Switching Frequency[kHz](typical)
800g/enclosed type:900g
232,900
140fix. (V1: +24V) / 70(V2:+5V)
Built to meet IEC61000-3-2
Convection
1mA(maximum) at 25
oC
,rated input/output and rated input frequency
Line Conducted Noise
Built to meet FCC Part15-B Class B
Built to meet VCCI Class B
Built to meet EN55022 Class B
Primary-Secondary-Frame Ground 50MOhm(minimum) by DC500V
Vibration
5-10Hz:10mm double amplitude,10-55Hz:19.6m/s
2
,20minutes' period for
60minutes each along X,Y,Z axes(non-operating)
294m/s
2
20 to 85%/RH(non-condensing)
-20 to +85
oC
10 to 85%/RH(non-condensing)
Withstanding Voltage
Primary-Secondary AC3,000V for 1minute at 25mA
Primary-Frame Ground AC2,500V for 1minute at 25mA
Secondary-Frame Ground AC500V for 1minute at 50mA
not available
not available
Environmental
-10 to +50
o
C(without cover) -10 to +45
o
C(with cover)
Automatic recovery
output shutdown(to reset,leave 3minutes after shut-off)
not available
not available
1.0mS(typical)
1,000mS(maximum) at 25C,24V output and AC85V input
20mS(minimum) at 25C,24V output and AC85V input
Functions
0.03%/
o
C
135
40
720
150
120
25
240
50
+/- 10% of Rated Output Voltage(at no load within the input range)
250
150
24
5
4(Peak14)
5
Single
22A(maximum) at AC100V/50A(maximum) at AC230V
76 at AC100V/79 at AC230V
0.97 at AC100V/0.90 at AC230V
2.1-0.9A
AC85-264V
50/60Hz
47-63Hz
Model
PFD21HWX
Input Characteristic
AC100-230V
120 WATT
AC-DC
CONVERTER
PFD-HWX 2 OUTPUT