ETA-USA Tel: 408-778-2793 Fax: 408-779-2753 e-mail: sales@eta-usa.com
VTC**SA Specification
Specifications<AC/DC>
VTC**SA
75W ATTS/SIN G LE O U TPU T
Output Voltage [V]
5
12
15
24
48
Output Current [A]
15.0
6.3
5.0
3.2
1.5
Voltage Adjust Range
Ripple and Noise [mVp-p](maximum) *3
100
170
200
290
530
Regulation
a.Statistic Line Regulation [mV](maximum)
40
96
120
192
384
b.Statistic Load Regulation [mV](maximum)
45
108
135
216
432
c.Temperature Coefficient *4
d.Drift[mV](maximum) *5
40
75
90
135
255
150
360
450
720
1440
f.Recovery Time *6
Rise up time
300mS(maximum)
Hold up time
Overcurrent Protection
Overvoltage Protection
Remote Sense
Remote On/Off
Operating Temperature
Operating Humidity
Storage Temperature
Storage Humidity
Isolation Resistance
Vibration
Shock
Cooling
? Leakage Current
? Line Conduction Noise
? Safety
? Weight (typical)
? MTBF [H]
? Switching Frequency[kHz](typical)
*6 when output current changed from 25% to 75% of rated output current rapidly at AC100V input
*2 at DC130V and rated output
*3 measured by a bayonet probe at the output connector at a 0 to 100MHz bandwidth
*4 at 0 to +50
*5 for 7hour period after 1hour warm-up at 25 and rated input/output
730,000
77
Conditions:
*1 at cold start
1.0mA(maximum)
Not specified
-
540g
Primary-Secondary-Frame Ground 50M(minimum) by DC500V insulation tester
5-10Hz:10mm double amplitude,10-55Hz:19.6m/s
2
,20minutes' period for 60minutes each along X,Y,Z axes(non-operating)
294m/s
2
Convection
30 to 85%RH(non-condensing)
Primary-Secondary AC1,500Vfor 1minute
Primary-Frame Ground AC1,500V for 1minute
Secondary-Frame Ground AC500V for 1minute
20mS(minimum) at 25 and rated input/output
Current Limiting with automatic recovery
output shutdown
not available
Model
VTC05SA
VTC12SA
VTC15SA
VTC24SA
VTC48SA
O utput C haracteristic
+/-10% of Rated Output Voltage(at no load within input range)
Functions
not available
0.03%/
Environm ental
0 to +50
85%RH(non-condensing)
-20 to +85
Withstanding Voltage
0.5mS(typical)
100mS(maximum) at 25 and rated input/output