Specifications<AC/DC>
BSB**SA
60/80WATTS/SINGLE
Input Voltage
Input Range
Input Frequency
Input Frequency Range
Phase
Inrush Current *1
Efficiency [%] (typical) *2
84
86
Single
30A(maximum) at AC100V
AC100V(DC130V)
AC85-132V(DC110-175V)
50/60Hz
47-440Hz
Model
BSB12SA
BSB24HSA
Input Characteristic
60 WATT
AC-DC
CONVERTER
Specifications<AC/DC>
BSB**SA-HAS
60/80W ATTS/SINGLE
Output Voltage [V]
12
24
Output Current [A]
5.0
3.3
Voltage Adjust Range
Ripple and Noise [m Vp-p](m axim um ) *3
170
300
Regulation
a.Statistic Line Regulation [mV](maximum)
96
192
b.Statistic Load Regulation [m V](m axim um)
108
216
c.Tem perature Coefficient *4
d.Drift[mV](maximum) *5
75
135
e.Dynam ic Load Regulation [m V](typical) *6
360
720
f.Recovery Time *6
40mS
40mS
Rise up time
Hold up time
5.5
3.5
14
28
Remote Sense
Remote On/Off
Operating Temperature
Operating Hum idity
Storage Tem perature
Storage Humidity
Isolation Resistance
Vibration
Shock
Cooling
Leakage Current
Line Conducted Noise
W eight (typical)
MTBF [H]
Switching Frequency[kHz](typical) *7
90
100
*7 variable on input voltage and load conditions
capacitor and 0.1uF film capacitor in parallel at a 0 to 100MHz bandwidth
*4 at -10 to +50
*5 for 7hour period after 1hour warm-up at 25 and rated input/output
*6 when output current changed from 25% of rated output current to 75% rapidly at AC100V input
Conditions:
*1at cold start
*2 at DC130V input/rated output
*3 measured by a bayonet probe at the end of a pair of 15cm long wires terminated with a 100uF electrolytic
600,000
Safety
Convection
0.5m A(maxim um) at 25C,rated input/output and rated input frequency
Built to m eet VCCI Class B
open board type:180g
Primary-Secondary-Frame Ground 50MOhm(minimum) by DC500V insulation tester
5-10Hz:10mm double amplitude,10-55Hz:19.6m/s
2
,20minutes' period for 60minutes each along X ,Y,Z axes(non-operating)
294m/s
2
20 to 90%RH(non-condensing)
W ithstanding Voltage
Primary-Secondary AC1,500V for 1minute
Primary-Frame Ground AC1,500V for 1minute
Secondary-Frame Ground AC500V for 1minute
Environmental
-10 to +50C
20 to 90%RH(non-condensing)
-20 to +85C
Overvoltage Protection [V]
Output shutdown(to reset,leave 30seconds after shut-off)
not available
not available
20mS(minim um) at 25C and rated input/output
Functions
Overcurrent Protection [ A]
Current Lim iting with automatic recovery
+/- 10% of Rated Output Voltage(at no load within the input range)
0.03%/C
200mS(maximum) at 25C and rated input/output
Model
BSB12SA
BSB24HSA
Output Characteristic