ETA-USA Tel: 408-778-2793 Fax: 408-779-2753 e-mail: sales@eta-usa.com
Specifications<AC/DC>
BJD**SA
100WATTS/SINGLE
Output Voltage [V]
3.3
5
6
9
12
15
24
30
36
48
Output Current [A]
20
20
17
11
9.0
7.0
4.5
3.5
2.8
2.2
Voltage Adjust Range
2.7-3.63V
Ripple and Noise [mVp-p](maximum) *3
150
150
160
180
180
180
180
200
300
400
Regulation
a.Statistic Line Regulation [mV](maximum)
40
40
48
72
96
120
192
240
288
384
b.Statistic Load Regulation [mV](maximum)
40
45
54
81
108
135
216
270
324
432
c.Temperature Coefficient *4
d.Drift[mV](maximum) *5
40
35
45
60
75
90
135
165
195
255
Rise up time
Hold up time
Overcurrent Protection *6
Overvoltage Protection >=115% of Rated
Output Voltage[V]
Remote Sense
Operating Temperature
Operating Humidity
Storage Temperature
Storage Humidity
Withstanding Voltage
Isolation Resistance
Vibration
Shock
Cooling
Leakage Current *7
Line Conducted Noise
Weight (typical)
MTBF [H]
457,000
457,000
455,000
458,000
458,000
546,000
563,000
555,000
557,000
554,000
Switching Frequency[kHz](typical)
300g(board type switcher)
100
Convection
0.75mA(maximum)
Built to meet FCC Part15-B Class B
Built to meet VCCI Class B
Secondary-Frame Ground AC500V for 1minute at 20mA
Primary-Secondary-Frame Ground 100MOhm(minimum) by DC500V insulation tester
5-10Hz:10mm double amplitude,10-55Hz:19.6m/s
2
,20minutes' period for 60minutes each along X,Y,Z axes(non-operating)
196m/s
2
-20 to +85
o
C
20 to 85%RH(non-condensing)
Primary-Secondary AC2,000V for 1minute at 10mA
Primary-Frame Ground AC2,000V for 1minute at 10mA
not available
Environmental
-10 to 50
o
C
20 to 85%RH(non-condensing)
20mS(typical) at 25
o
C and rated input/output( >AC100V)
Functions
hiccup mode/automatic recovery(on and over 105% of Rated Output Current[A] )
output shutdown(on and over 115% of Rated Output Voltage[V] )
BJD48SA-U
+/- 10% of Rated Output Voltage(at no load within the input range)
0.03%/
o
C
700mS(maximum) at 25
o
C and rated input/output
Model
BJD3.3SA-U BJD05SA-U BJD06SA-U
BJD09SA-U
BJD12SA-U BJD15SA-U BJD24SA-U
BJD30SA-U
BJB36SA-U
Specifications<AC/DC>
B JD**S A
100W ATTS /S INGLE
Input Volt age
Input Range
Input Frequency
Input Frequency Range
P hase
Inrush Current *1
Efficiency [%] (t ypical) *2
80
84
84
85
85
85
85
85
85
85
Model
BJD3.3SA-U
BJD 05SA-U
BJD06SA-U BJD09SA-U BJD12SA-U BJD15SA-U
BJD24SA-U
BJD30SA-U BJD36SA-U
BJD48SA-U
In pu t C h aracte ristic
AC100-115V
AC85-132V(DC110-175V)
50/60Hz
47-440Hz
Single
30A(t ypical) at AC100V
100 WATT
AC-DC
CONVERTER
BJD-SA SINGLE OUTPUT