ETA-USA Tel: 408-778-2793 Fax: 408-779-2753 e-mail: sales@eta-usa.com
Specifications<AC/DC>
SVM **SB
15W AT T S/SING LE
O utput Voltage [V]
5
12
15
24
48
O utput Current [A]
3.0
1.3
1.0
0.7
0.35
Voltage Adjust Range
Ripple and Noise [m Vp-p](m axim um ) *3
150
220
250
340
580
Regulation
a.Statistic Line Regulation [m V](m axim um )
40
96
120
192
384
b.Statistic Load Regulation [m V](m axim um )
45
108
135
216
432
c.Tem perature Coefficient *4
d.Drift[m V](m axim um ) *5
40
75
90
135
255
e.Dynam ic Load Regulation [m V](typical) *6
150
360
450
720
1440
f.Recovery Tim e *6
Rise up tim e
Hold up tim e
3.30
1.43
1.10
0.77
0.38
5.50
13.2
16.50
26.4
52.8
Rem ote Sense
Rem ote O n/O ff
O perating Tem perature
O perating Hum idity
Storage Tem perature
Storage Hum idity
Vibration
Shock
Cooling
Leak age Current
Safety
W eight (typical)
M TBF [H]
Sw itching Frequency[k Hz](typical)
*4 at 0 to +50
*5 for 7hour period after 1hour warm -up at 25 and rated input/output
*6 when output current changed from 25% to 75% of rated output current rapidly at AC200V input
Conditions:
*1 at cold start
*2 at DC260V input and rated output
*3 m easured by a bayonet probe at output connector at 0 to 100M Hz bandwidth
M odel
SVM 05SB
SVM 12SB
SVM 15SB
SVM 24SB
SVM 48SB
+/- 10% of Rated O utput Voltage(at no load w ithin the input range)
0.03% /
0.3m S(typical)
500m S(m axim um ) at 25 and rated input/output
15m S(m inim um ) at 25 and rated input/output
Functions
O vercurrent Protection 110% of
Rated O utput Current[A]
Current Lim iting w ith autom atic recovery
O vervoltage Protection 110% of
Rated O utput Voltage[V]
output shutdow n(to reset,leave 1m inute after shut-off)
not available
not available
Environm ental
0 to +50
85% RH(non-condensing)
-20 to +85
85% RH(non-condensing)
W ithstanding Voltage
Prim ary-Secondary AC2,500V for 1m inute
Prim ary-Fram e G round AC2,500V for 1m inute
Secondary-Fram e G round AC500V for 1m inute
Isolation Resistance
Prim ary-Secondary-Fram e G round 50M (m inim um ) by DC500V insulation
tester
5-10Hz:10m m double am plitude,10-55H z:19.6m /s
2
,20m inutes' period for 60m inutes each along X ,Y,Z axes(non-operating)
120g
600,000
140
294m /s
2
Convection