ETA-USA Tel: 408-778-2793 Fax: 408-779-2753 e-mail: sales@eta-usa.com
Specifications<AC/DC>
BJS**FWA-U
10WATTS/2OUTPUTS
Output Voltage [V]
12
12
15
15
5
12
12
5
Output Current [A]
0.6
0.3
0.4
0.3
1.2
0.3
0.7
0.3
Voltage Adjust Range
Voltage Tolerance [mVp-p](typical)
+/-0.12
11.28-11/48
+/-0.15
14.1-15.6
+/-0.1
11.28-12.48
+/-0.12
4.7-5.2
Ripple and Noise [mVp-p](maximum) *3
220
220
250
250
150
220
220
150
Regulation
a.Statistic Line Regulation [mV](maximum)
b.Statistic Load Regulation [mV](maximum)
c.Temperature Coefficient *4
d.Drift[mV](maximum) *5
e.dynamic load regulation [mV](typical) *6
f.Recovery Time *6
Rise up time
Hold up time
Overcurrent Protection 110%
of Rated Output Current[A]
Overvoltage Protection 115%
of Rated Output Voltage[V]
Remote Sense
Remote On/Off
Power Fail Detection
Parallel/series Operation
Operating Temperature
Operating Humidity
Storage Temperature
Storage Humidity
Withstanding Voltage
Isolation Resistance
Vibration
Shock
Cooling
Leakage Current
Line Conducted Noise
Safety
Weight (typical)
MTBF [H]
Switching Frequency[kHz](typical)
*6 when output current changed from 25% to 75% of rated output current rapidly at rated input
capacitor and 0.1uF film capacitor in parallel at a 0 to 100MHz bandwidth
*3 when output current changed from 0mA to rated output current
*4 at -10 to +40
*5 for 7hour period after 1hour warm-up at 25 and rated input/output
Output
Conditions:
*1at cold start
*2 measured by a bayonet probe at the end of a pair of 5cm long wires terminated with a 100uF electrolytic
1,200,000
110kHz at rated input/output
90 to 600kHz at input voltage of AC85 to 132V with a load of 0 to 100%
Built to meet VCCI Class B
UL: UL1950
C-UL: CSA C22.2 No.950
35g
196m/s
2
Convection
55uA(typical) at 25,50Hz and AC100V input
Built to meet FCC Part15-B Class B
Primary-Frame Ground AC1,500V for 1minute
Secondary-Frame Ground AC500V for 1minute
Primary-Secondary-Frame Ground 50M(minimum) by DC500V insulation tester
5-10Hz:10mm double amplitude,10-55Hz:19.6m/s
2
,20minutes' period for 60minutes each along X,Y,Z axes(non-operating)
20 to 90%RH(non-condensing)
-20 to +85
10 to 85%RH(non-condensing)
Primary-Secondary AC1,500V for 1minute
not available
not available
Environmental
-10 to +71( -10 to 50 at full load condition)
V1=Current Limiting with automatic recovery
zener diode clamping
not available
not available
20mS(typical)
200mS(maximum) at 25 and rated input/output
20mS(typical) at 25 and rated input/output
Functions
+/-360
+/-450
+/-150
+/-360
0.03%/
75
90
40
75
108
135
45
108
not available
96
120
40
96
Model
BJS22FWA-U
BJS23FWA-U
BJS24FWA-U
BJS24FWA-B-U